Close Go back Collapse all sections
Process Data set: Aerial Bunched XLPE Cable (3*70+1*54.6 SQMM) (en) en

Key Data Set Information
Reference year 2026
Name
Aerial Bunched XLPE Cable (3*70+1*54.6 SQMM)
Technical purpose of product or process Aerial Bunched Cables (ABC) are overhead power cables comprising multiple insulated single-core conductors bundled into a compact assembly. This Environmental Product Declaration (EPD) covers the Aerial Bunched Cable with a conductor configuration of 3 × 70 mm² + 1 × 54.6 mm², manufactured by APAR Industries. The cable is a low-voltage, heavy-duty product insulated with XLPE and designed to provide reliable electrical, mechanical, and thermal performance in outdoor overhead distribution networks. Compared to conventional bare conductors, this ABC configuration offers improved electrical strength retention, higher short-circuit withstand capability, and enhanced resistance to moisture and surge currents, ensuring long service life and dependable operation in industrial, commercial, and utility applications. The Global Warming Potential (GWP-total) results for the alternative variant, Aerial Bunched Cable (3 × 35 mm² + 1 × 54.6 mm²), are included in the annex for reference. Features: • Long service life with defect-free insulation • High electrical and mechanical strength • Resistance to moisture and surge currents • Lower laying and installation costs due to smaller diameter and bending radius
Classification
Class name : Hierarchy level
  • One Click LCA: Material / Building Technology / Cables
General comment on data set Aerial Bunched Cables (ABC) are overhead power cables comprising multiple insulated single-core conductors bundled into a compact assembly. This Environmental Product Declaration (EPD) covers the Aerial Bunched Cable with a conductor configuration of 3 × 70 mm² + 1 × 54.6 mm², manufactured by APAR Industries. The cable is a low-voltage, heavy-duty product insulated with XLPE and designed to provide reliable electrical, mechanical, and thermal performance in outdoor overhead distribution networks. Compared to conventional bare conductors, this ABC configuration offers improved electrical strength retention, higher short-circuit withstand capability, and enhanced resistance to moisture and surge currents, ensuring long service life and dependable operation in industrial, commercial, and utility applications. The Global Warming Potential (GWP-total) results for the alternative variant, Aerial Bunched Cable (3 × 35 mm² + 1 × 54.6 mm²), are included in the annex for reference. Features: • Long service life with defect-free insulation • High electrical and mechanical strength • Resistance to moisture and surge currents • Lower laying and installation costs due to smaller diameter and bending radius
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Material properties of the reference flow
    • weight per piece: 0.977 kg
    • linear density: 0.977 kg/m
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.0 kg
Time representativeness
Data set valid until 2031
Technological representativeness
Technology description including background system Aerial Bunched Cables (ABC) are overhead power cables comprising multiple insulated single-core conductors bundled into a compact assembly. This Environmental Product Declaration (EPD) covers the Aerial Bunched Cable with a conductor configuration of 3 × 70 mm² + 1 × 54.6 mm², manufactured by APAR Industries. The cable is a low-voltage, heavy-duty product insulated with XLPE and designed to provide reliable electrical, mechanical, and thermal performance in outdoor overhead distribution networks. Compared to conventional bare conductors, this ABC configuration offers improved electrical strength retention, higher short-circuit withstand capability, and enhanced resistance to moisture and surge currents, ensuring long service life and dependable operation in industrial, commercial, and utility applications. The Global Warming Potential (GWP-total) results for the alternative variant, Aerial Bunched Cable (3 × 35 mm² + 1 × 54.6 mm²), are included in the annex for reference. Features: • Long service life with defect-free insulation • High electrical and mechanical strength • Resistance to moisture and surge currents • Lower laying and installation costs due to smaller diameter and bending radius

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 5.67
  • ND
  • ND
  • ND
  • 0.368
  • 0
  • 0.00436
  • -1.95
  • -1.56
  • -22.6
Input
  • 3.65
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • -2.26
  • -1.39
  • 0.201
Input
  • 9.32
  • ND
  • ND
  • ND
  • 0.368
  • ND
  • 0.00436
  • -4.21
  • -2.95
  • -22.4
Input
  • 73.8
  • ND
  • ND
  • ND
  • 0.117
  • 0
  • 0.301
  • -8.02
  • -2.82
  • -62.8
Input
  • 12.1
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • -8.8
  • -3.29
  • 2.91
Input
  • 85.9
  • ND
  • ND
  • ND
  • 0.117
  • ND
  • 0.301
  • -16.82
  • -6.11
  • -59.89
Input
  • 0.324
  • ND
  • ND
  • ND
  • 0.00015
  • 0
  • 0.000135
  • 0.000539
  • 0.0000437
  • 0.66
Input
  • 0.0997
  • ND
  • ND
  • ND
  • 0.00000714
  • 0
  • 0.00000171
  • 0.0000115
  • 6.8E-7
  • -0.000122
Input
  • 0
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.0293
  • ND
  • ND
  • ND
  • 0.000288
  • 0
  • 0.0000407
  • 0.000205
  • -0.00126
  • -0.159
Output
  • 0.967
  • ND
  • ND
  • ND
  • 0.00128
  • 0
  • 0.000502
  • 0.00623
  • 0.000618
  • -0.788
Output
  • 3.99
  • ND
  • ND
  • ND
  • 0.0303
  • 0
  • 0.00961
  • 0.287
  • 1.75
  • -10.1
Output
  • 0.000103
  • ND
  • ND
  • ND
  • 1.93E-7
  • 0
  • 6.81E-8
  • 2.96E-7
  • 4.82E-8
  • -0.000265
Output
  • 0
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.0309
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • 0.674
  • 0
  • 0
Output
  • 0
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • 2.59
  • 0
  • 0
Output
  • 0
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • 1.5
  • 0
  • 0

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
  • 86.4
  • ND
  • ND
  • ND
  • 0.117
  • 0
  • 0.301
  • 0.307
  • 0.114
  • -62.7
  • 0.0000159
  • ND
  • ND
  • ND
  • 5.98E-7
  • 0
  • 6.85E-8
  • 9.13E-7
  • 1.56E-8
  • -0.00000843
  • 0.0311
  • ND
  • ND
  • ND
  • 0.0000704
  • 0
  • 0.0000704
  • 0.000258
  • 0.0000379
  • -0.0243
  • 4.02E-7
  • ND
  • ND
  • ND
  • 8.43E-10
  • 0
  • 3.28E-10
  • 3.06E-10
  • 1.26E-10
  • -6.91E-8
  • 0.000357
  • ND
  • ND
  • ND
  • 0.00000587
  • 0
  • 0.00000161
  • 0.0000107
  • 0.00000155
  • -0.00206
  • 0.00461
  • ND
  • ND
  • ND
  • 0.0000107
  • 0
  • 0.000023
  • 0.0000849
  • 0.0000642
  • -0.00331
  • 0.0509
  • ND
  • ND
  • ND
  • 0.000112
  • 0
  • 0.000251
  • 0.000853
  • 0.000147
  • -0.0302
  • -0.402
  • ND
  • ND
  • ND
  • 0.0000198
  • 0
  • 0.00000366
  • 0.251
  • 0.154
  • 0.0173
  • 6.42
  • ND
  • ND
  • ND
  • 0.00902
  • 0
  • 0.0213
  • 0.464
  • 0.0143
  • -3.85
  • 0.0014
  • ND
  • ND
  • ND
  • 0.000018
  • 0
  • 0.00000904
  • 0.0000353
  • 0.00000717
  • -0.0881
  • 6.019
  • ND
  • ND
  • ND
  • 0.009058
  • 0
  • 0.02131
  • 0.715
  • 0.1683
  • -3.921
  • 0.0162
  • ND
  • ND
  • ND
  • 0.0000404
  • 0
  • 0.000101
  • 0.000238
  • 0.000052
  • -0.0137
  • 4.03
  • ND
  • ND
  • ND
  • 0.0123
  • 0
  • 0.00143
  • 0.0171
  • 0.00195
  • -7.25

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Incidence of disease due to PM emissions (PM) 2
  • 3.35E-7
  • ND
  • ND
  • ND
  • 6.53E-10
  • 0
  • 1.75E-9
  • 3.14E-9
  • 7.54E-10
  • -2.7E-7
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 91.4
  • ND
  • ND
  • ND
  • 0.563
  • 0
  • 0.0451
  • 0.241
  • 29.6
  • -9.34
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 9.45E-9
  • ND
  • ND
  • ND
  • 6.41E-12
  • 0
  • 3.61E-12
  • 3.27E-11
  • 3.92E-12
  • -6.41E-9
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 3.54E-7
  • ND
  • ND
  • ND
  • 4.25E-10
  • 0
  • 1.89E-10
  • 1.62E-9
  • 7.89E-10
  • -4.72E-8
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.0968
  • ND
  • ND
  • ND
  • 0.000772
  • 0
  • 0.000277
  • 0.00119
  • 0.000197
  • -0.999
Soil quality index (SQP) 2
  • 57
  • ND
  • ND
  • ND
  • 0.0639
  • 0
  • 0.198
  • 0.433
  • 0.208
  • -4.46