Close Go back Collapse all sections
Process Data set: 1.25m Roll Panel Vent (en) en

Key Data Set Information
Reference year 2026
Name
1.25m Roll Panel Vent
Technical purpose of product or process The G504 is a 1.25m wide Roll Panel Vent designed to maintain an air gap between the underside of the roofing membrane or sarking board and loft insulation at the eaves, to provide a continuous flow of air into the roof space. The castellated profile is suitable for either 400mm, 450mm, or 600mm rafter centres, ideal for both new build and refurbishment where rafter centres are not consistent or unknown. The extra width of the panel allows for better coverage when lower pitch and deeper insulation details are encountered.
Classification
Class name : Hierarchy level
  • One Click LCA: Material / Plastic Membrane Roofing / Plastics Other
General comment on data set The G504 is a 1.25m wide Roll Panel Vent designed to maintain an air gap between the underside of the roofing membrane or sarking board and loft insulation at the eaves, to provide a continuous flow of air into the roof space. The castellated profile is suitable for either 400mm, 450mm, or 600mm rafter centres, ideal for both new build and refurbishment where rafter centres are not consistent or unknown. The extra width of the panel allows for better coverage when lower pitch and deeper insulation details are encountered.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Material properties of the reference flow
    • weight per piece: 4.1 kg
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.0 kg
Time representativeness
Data set valid until 2031
Technological representativeness
Technology description including background system The G504 is a 1.25m wide Roll Panel Vent designed to maintain an air gap between the underside of the roofing membrane or sarking board and loft insulation at the eaves, to provide a continuous flow of air into the roof space. The castellated profile is suitable for either 400mm, 450mm, or 600mm rafter centres, ideal for both new build and refurbishment where rafter centres are not consistent or unknown. The extra width of the panel allows for better coverage when lower pitch and deeper insulation details are encountered.

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 32.9
  • 0.0573
  • -29.5
  • ND
  • 0
  • 0.0128
  • 0.0758
  • 0.00432
  • -14.4
Input
  • 24.7
  • 0
  • -24.7
  • ND
  • 0
  • 0
  • 0
  • 0
  • 12.2
Input
  • 57.6
  • 0.0573
  • -54.2
  • ND
  • ND
  • 0.0128
  • 0.0758
  • 0.00432
  • -2.2
Input
  • 8.44
  • 3.26
  • 0.193
  • ND
  • 0
  • 0.934
  • -118
  • -43.2
  • -109
Input
  • 96
  • 0
  • -1.89
  • ND
  • 0
  • 0
  • -68.7
  • -25.4
  • 31.5
Input
  • 104.4
  • 3.26
  • -1.697
  • ND
  • ND
  • 0.934
  • -186.7
  • -68.6
  • -77.5
Input
  • 5.35
  • 0.00153
  • 0.000782
  • ND
  • 0
  • 0.000398
  • 0.00403
  • 0.0000998
  • 1.34
Input
  • 0.643
  • 0.0000182
  • 0.00000647
  • ND
  • 0
  • 0.00000505
  • 0.0000291
  • 0.00000187
  • -0.000101
Input
  • 0
  • 0
  • 0
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.0596
  • 0.000494
  • -0.00188
  • ND
  • 0
  • 0.000138
  • 0.00131
  • -0.0041
  • -0.0279
Output
  • 0.347
  • 0.00536
  • 0.00765
  • ND
  • 0
  • 0.00158
  • 0.054
  • 0.000485
  • -0.186
Output
  • 19.6
  • 0.11
  • 3.49
  • ND
  • 0
  • 0.0293
  • 2.46
  • 5.51
  • -24.2
Output
  • 0.000293
  • 0.000001
  • 7.55E-7
  • ND
  • 0
  • 1.99E-7
  • 0.00000119
  • 6.71E-8
  • -0.000193
Output
  • 0
  • 0
  • 0
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.601
  • 0
  • 0.917
  • ND
  • 0
  • 0
  • 0.94
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 2.53
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 1.47
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
  • 1.3E+2
  • 3.26
  • 0.869
  • ND
  • 0
  • 0.934
  • 1
  • 0.276
  • -99.6
  • 0.0000588
  • 7.8E-7
  • 2.65E-7
  • ND
  • 0
  • 1.8E-7
  • 7.03E-7
  • 2.8E-8
  • -0.0000197
  • 0.0271
  • 0.000737
  • 0.00035
  • ND
  • 0
  • 0.000219
  • 0.000932
  • 0.0000883
  • -0.0183
  • 0.0000149
  • 3.8E-9
  • 9.96E-10
  • ND
  • 0
  • 9.5E-10
  • 1.16E-9
  • 3.21E-10
  • -1.22E-7
  • 0.0025
  • 0.0000179
  • 0.0000173
  • ND
  • 0
  • 0.00000501
  • 0.0000232
  • 0.00000131
  • -0.00196
  • 0.00654
  • 0.000239
  • 0.000419
  • ND
  • 0
  • 0.0000721
  • 0.000489
  • 0.000294
  • -0.0032
  • 0.055
  • 0.0026
  • 0.00135
  • ND
  • 0
  • 0.000785
  • 0.00429
  • 0.00036
  • -0.0322
  • -2.57
  • 0.0000515
  • 2.84
  • ND
  • 0
  • 0.0000146
  • -0.000101
  • -0.0000699
  • -1.31
  • 6.68
  • 0.228
  • 0.0886
  • ND
  • 0
  • 0.0644
  • 5.52
  • 0.133
  • -3.9
  • 0.034
  • 0.0000983
  • 0.0000835
  • ND
  • 0
  • 0.0000288
  • 0.000102
  • 0.00000811
  • -0.0000998
  • 4.144
  • 0.2281
  • 2.929
  • ND
  • 0
  • 0.06444
  • 5.52
  • 0.1329
  • -5.21
  • 0.0249
  • 0.0011
  • 0.000457
  • ND
  • 0
  • 0.000323
  • 0.00111
  • 0.000156
  • -0.0179
  • 2.44
  • 0.017
  • 0.0239
  • ND
  • 0
  • 0.00461
  • 0.16
  • 0.00135
  • -0.695

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Incidence of disease due to PM emissions (PM) 2
  • 2.59E-7
  • 1.92E-8
  • 5.83E-9
  • ND
  • 0
  • 6.44E-9
  • 7.52E-9
  • 2E-9
  • -1.2E-7
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 104
  • 0.505
  • 0.899
  • ND
  • 0
  • 0.132
  • 1.53
  • 0.411
  • -7.51
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 4.58E-9
  • 3.93E-11
  • 3.9E-11
  • ND
  • 0
  • 1.06E-11
  • 2.31E-10
  • 6.49E-12
  • -6.01E-10
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 7.42E-8
  • 2.06E-9
  • 2.1E-9
  • ND
  • 0
  • 6.05E-10
  • 8.89E-9
  • 1.28E-9
  • -2.96E-8
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 1.14
  • 0.00405
  • 0.003
  • ND
  • 0
  • 0.000814
  • 0.00468
  • 0.000274
  • -0.752
Soil quality index (SQP) 2
  • 204
  • 2.58
  • 0.777
  • ND
  • 0
  • 0.941
  • 1.04
  • 0.643
  • -75.3