Key Data Set Information
Reference year 2026
Name
CASA R4-C
Technical purpose of product or process The air handling unit is a device, which will provide healthy dust free air to buildings with a good energy efficiency. Energy efficiency is created with a good design and optimization between fans, heat exchanger, filtration, control and modular space requirements. Swegon CASA products are known in the market for their high quality, energy efficiency, silence and ease of use. Swegon CASA R4-C is residential ventilation unit (1050 x 700 x 296 mm, Ø 160 mm) with rotary heat exchanger for apartments under 170 m². Air flow range 72 - 331 m³/h. Flat design and compact size enables various mounting options, also ideal for ceiling mounting as height under 30 cm. The market’s most intelligent humidity control as standard. Developed, manufactured and tested for Nordic climate.
Classification
Class name : Hierarchy level
  • One Click LCA: Material / Building Technology / HVAC
General comment on data set The air handling unit is a device, which will provide healthy dust free air to buildings with a good energy efficiency. Energy efficiency is created with a good design and optimization between fans, heat exchanger, filtration, control and modular space requirements. Swegon CASA products are known in the market for their high quality, energy efficiency, silence and ease of use. Swegon CASA R4-C is residential ventilation unit (1050 x 700 x 296 mm, Ø 160 mm) with rotary heat exchanger for apartments under 170 m². Air flow range 72 - 331 m³/h. Flat design and compact size enables various mounting options, also ideal for ceiling mounting as height under 30 cm. The market’s most intelligent humidity control as standard. Developed, manufactured and tested for Nordic climate.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Material properties of the reference flow
    • weight per piece: 67.499 kg
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.0 kg
Time representativeness
Data set valid until 2031
Technological representativeness
Technology description including background system The air handling unit is a device, which will provide healthy dust free air to buildings with a good energy efficiency. Energy efficiency is created with a good design and optimization between fans, heat exchanger, filtration, control and modular space requirements. Swegon CASA products are known in the market for their high quality, energy efficiency, silence and ease of use. Swegon CASA R4-C is residential ventilation unit (1050 x 700 x 296 mm, Ø 160 mm) with rotary heat exchanger for apartments under 170 m². Air flow range 72 - 331 m³/h. Flat design and compact size enables various mounting options, also ideal for ceiling mounting as height under 30 cm. The market’s most intelligent humidity control as standard. Developed, manufactured and tested for Nordic climate.

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Replacement
B4
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 336
  • 2.04
  • -171
  • ND
  • 43.7
  • 2.75E+4
  • 0
  • 0.148
  • 0.43
  • 0.013
  • -89.1
Input
  • 145
  • 0
  • -145
  • ND
  • 0
  • 0
  • 0
  • 0
  • -0.0127
  • 0
  • 72.6
Input
  • 481
  • 2.04
  • -316
  • ND
  • 43.7
  • 2.75E+4
  • ND
  • 0.148
  • 0.4173
  • 0.013
  • -16.5
Input
  • 2.73E+3
  • 134
  • -8.66
  • ND
  • 357
  • 1.02E+5
  • 0
  • 8.7
  • -2.5E+2
  • 1.35
  • -764
Input
  • 308
  • 0
  • -25.6
  • ND
  • 0
  • 0
  • 0
  • 0
  • -282
  • -0.399
  • 2.44
Input
  • 3038
  • 134
  • -34.26
  • ND
  • 357
  • 1.02E+5
  • ND
  • 8.7
  • -532
  • 0.951
  • -761.6
Input
  • 16.8
  • 0.0607
  • 0.00468
  • ND
  • 0.224
  • 16.4
  • 0
  • 0.00396
  • 0.0205
  • 0.000339
  • 48.4
Input
  • 3.86
  • 0.000646
  • 0.0000445
  • ND
  • 0.00213
  • 0.141
  • 0
  • 0.0000501
  • 0.000159
  • 0.00000701
  • -0.00696
Input
  • 0.109
  • 0
  • 0
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 78.8
  • 0.0161
  • -0.0103
  • ND
  • 0.437
  • 66.3
  • 0
  • 0.00118
  • 0.0249
  • 0.0014
  • -0.135
Output
  • 7.78
  • 0.186
  • 0.059
  • ND
  • 4.01
  • 247
  • 0
  • 0.0126
  • 0.373
  • 0.00149
  • -27.7
Output
  • 357
  • 3.68
  • 13
  • ND
  • 186
  • 2.08E+4
  • 0
  • 0.264
  • 9.69
  • 0.034
  • -219
Output
  • 0.0136
  • 0.0000366
  • 0.00000451
  • ND
  • 0.000738
  • 0.731
  • 0
  • 0.00000269
  • 0.00000628
  • 2.06E-7
  • 0.000873
Output
  • 0.00413
  • 0
  • 0
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 1.41
  • 0
  • 5.46
  • ND
  • 0
  • 0
  • 0
  • 0
  • 50.6
  • 0
  • 0
Output
  • 0.606
  • 0
  • 3.16
  • ND
  • 10.3
  • 0
  • 0
  • 0
  • 8.1
  • 0
  • 0
Output
  • 0.00209
  • 0
  • 14.7
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 8.51
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Replacement
B4
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
  • 2.88E+3
  • 134
  • 5.37
  • ND
  • 999
  • 1.02E+5
  • 0
  • 8.7
  • 44.7
  • 1.35
  • -763
  • 0.0191
  • 0.0000269
  • 0.00000165
  • ND
  • 0.00049
  • 0.06
  • 0
  • 0.000002
  • 0.00000269
  • 8.72E-8
  • -0.000811
  • 0.92
  • 0.0884
  • 0.00227
  • ND
  • 0.225
  • 25.4
  • 0
  • 0.00195
  • 0.0328
  • 0.000389
  • -0.338
  • 0.0000334
  • 1.83E-7
  • 6.13E-9
  • ND
  • 0.0000707
  • 0.0000821
  • 0
  • 1.21E-8
  • 5.42E-8
  • 1.59E-9
  • -2.69E-7
  • 0.129
  • 0.000569
  • 0.000112
  • ND
  • 0.0138
  • 4.24
  • 0
  • 0.0000415
  • 0.00016
  • 0.00000451
  • -0.0386
  • 0.209
  • 0.0243
  • 0.00228
  • ND
  • 0.0585
  • 4.05
  • 0
  • 0.000655
  • 0.0156
  • 0.000148
  • -0.0768
  • 2.14
  • 0.268
  • 0.00897
  • ND
  • 0.503
  • 35.9
  • 0
  • 0.00712
  • 0.165
  • 0.00162
  • -0.839
  • -8.41
  • 0.00183
  • 11.4
  • ND
  • 0.157
  • 142
  • 0
  • 0.000127
  • 0.000946
  • -0.0000175
  • -7.83
  • 224
  • 9.81
  • 1.32
  • ND
  • 76.7
  • 4.42E+3
  • 0
  • 0.618
  • 22.7
  • 0.0549
  • -84.6
  • 0.331
  • 0.00376
  • 0.000508
  • ND
  • 0.0996
  • 13
  • 0
  • 0.000222
  • 0.000496
  • 0.0000314
  • 0.0105
  • 215.9
  • 9.816
  • 12.72
  • ND
  • 76.96
  • 4575
  • 0
  • 0.6183
  • 22.7
  • 0.05491
  • -92.42
  • 0.81
  • 0.0862
  • 0.00297
  • ND
  • 0.237
  • 11.5
  • 0
  • 0.00303
  • 0.0482
  • 0.00058
  • -0.283
  • 16.5
  • 0.595
  • 0.238
  • ND
  • 16.8
  • 2.85E+3
  • 0
  • 0.0428
  • 1.4
  • 0.00389
  • -11.9

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Replacement
B4
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Incidence of disease due to PM emissions (PM) 2
  • 0.0000176
  • 6.63E-7
  • 3.59E-8
  • ND
  • 0.0000024
  • 0.0000905
  • 0
  • 4.95E-8
  • 8.26E-7
  • 8.85E-9
  • -0.00000562
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 7.53E+3
  • 16
  • 35.7
  • ND
  • 2.38E+3
  • 1.41E+5
  • 0
  • 1.22
  • 49.2
  • 0.113
  • -208
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 3.75
  • 1.75E-9
  • 3E-10
  • ND
  • 5.5E-8
  • 0.00000132
  • 0
  • 1.05E-10
  • 2.06E-9
  • 1.01E-11
  • -1.34E-8
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 9.87
  • 7.36E-8
  • 1.42E-8
  • ND
  • 5.5E-7
  • 0.0000718
  • 0
  • 5.47E-9
  • 6.68E-8
  • 2.32E-10
  • -6.55E-7
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 9.79
  • 0.148
  • 0.0179
  • ND
  • 3.62
  • 2.85E+3
  • 0
  • 0.0108
  • 0.0254
  • 0.000846
  • 3.36
Soil quality index (SQP) 2
  • 1.65E+3
  • 65.8
  • 4.66
  • ND
  • 146
  • 1.99E+4
  • 0
  • 5.44
  • 4.05
  • 2.65
  • -593