Close Go back Collapse all sections
Process Data set: Electric domestic fan E-EXTRA (en) en

Key Data Set Information
Reference year 2026
Name
Electric domestic fan E-EXTRA
Technical purpose of product or process This Environmental Product Declaration covers the EUROPLAST EE100 domestic exhaust fan (Ø100), designed for residential ventilation applications (RVU). The unit provides mechanical air extraction by replacing indoor air with outdoor air, supporting adequate air exchange in residential and light-commercial interiors. It is intended for indoor wall installation and connects directly to Ø100 ventilation shafts or round duct systems. The housing, propeller, and front cover are manufactured from acrylonitrile-butadiene-styrene (ABS) and recycled polystyrene (rPS), providing durability, dimensional stability, and resistance to temperature variations and UV exposure. The lightweight and robust construction supports quick installation, stable operation, and low maintenance. The EE100 is designed to maintain efficient air exchange and support a healthy indoor environment throughout its service life. The use of recyclable plastic materials and essential safety features contributes to lower environmental impact and user comfort. Technical characteristics (EE100 – Ø100): • Axial fan; • Electrical connection: ~220–240 V, 50 Hz; • Power consumption: 15 W; • Airflow rate: 100 m³/h; • Fan speed: 2550 RPM; • Noise level at 3 m: 32 dB(A); • Protection rating: IPX4; • Insulation class: B; • Operating temperature range: +5 °C to +40 °C; • Duct diameter: 100 mm; • Product weight: 0.37 kg. Further information can be found at: http://www.europlast.lv.
Classification
Class name : Hierarchy level
  • One Click LCA: Material / Building Technology / HVAC
General comment on data set This Environmental Product Declaration covers the EUROPLAST EE100 domestic exhaust fan (Ø100), designed for residential ventilation applications (RVU). The unit provides mechanical air extraction by replacing indoor air with outdoor air, supporting adequate air exchange in residential and light-commercial interiors. It is intended for indoor wall installation and connects directly to Ø100 ventilation shafts or round duct systems. The housing, propeller, and front cover are manufactured from acrylonitrile-butadiene-styrene (ABS) and recycled polystyrene (rPS), providing durability, dimensional stability, and resistance to temperature variations and UV exposure. The lightweight and robust construction supports quick installation, stable operation, and low maintenance. The EE100 is designed to maintain efficient air exchange and support a healthy indoor environment throughout its service life. The use of recyclable plastic materials and essential safety features contributes to lower environmental impact and user comfort. Technical characteristics (EE100 – Ø100): • Axial fan; • Electrical connection: ~220–240 V, 50 Hz; • Power consumption: 15 W; • Airflow rate: 100 m³/h; • Fan speed: 2550 RPM; • Noise level at 3 m: 32 dB(A); • Protection rating: IPX4; • Insulation class: B; • Operating temperature range: +5 °C to +40 °C; • Duct diameter: 100 mm; • Product weight: 0.37 kg. Further information can be found at: http://www.europlast.lv.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Material properties of the reference flow
    • weight per piece: 0.389 kg
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.0 kg
Time representativeness
Data set valid until 2031
Technological representativeness
Technology description including background system This Environmental Product Declaration covers the EUROPLAST EE100 domestic exhaust fan (Ø100), designed for residential ventilation applications (RVU). The unit provides mechanical air extraction by replacing indoor air with outdoor air, supporting adequate air exchange in residential and light-commercial interiors. It is intended for indoor wall installation and connects directly to Ø100 ventilation shafts or round duct systems. The housing, propeller, and front cover are manufactured from acrylonitrile-butadiene-styrene (ABS) and recycled polystyrene (rPS), providing durability, dimensional stability, and resistance to temperature variations and UV exposure. The lightweight and robust construction supports quick installation, stable operation, and low maintenance. The EE100 is designed to maintain efficient air exchange and support a healthy indoor environment throughout its service life. The use of recyclable plastic materials and essential safety features contributes to lower environmental impact and user comfort. Technical characteristics (EE100 – Ø100): • Axial fan; • Electrical connection: ~220–240 V, 50 Hz; • Power consumption: 15 W; • Airflow rate: 100 m³/h; • Fan speed: 2550 RPM; • Noise level at 3 m: 32 dB(A); • Protection rating: IPX4; • Insulation class: B; • Operating temperature range: +5 °C to +40 °C; • Duct diameter: 100 mm; • Product weight: 0.37 kg. Further information can be found at: http://www.europlast.lv.

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 3.9
  • 0.0538
  • -2.27
  • 0
  • 0
  • 0
  • 0
  • 0
  • 14.3
  • 0
  • 0
  • 0.00179
  • 0.0252
  • 0.000648
  • -2.07
Input
  • 2.31
  • 0
  • -2.31
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • -0.00237
  • 1.49
Input
  • 6.21
  • 0.0538
  • -4.58
  • ND
No records found.
No records found.
No records found.
No records found.
  • 14.3
No records found.
  • ND
  • 0.00179
  • 0.0252
  • -0.001722
  • -0.58
Input
  • 24
  • 3.08
  • 0.151
  • 0
  • 0
  • 0
  • 0
  • 0
  • 156
  • 0
  • 0
  • 0.113
  • -3.24
  • -2.16
  • -2.57
Input
  • 0.112
  • 0
  • -0.108
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • -0.000453
  • 0.0198
Input
  • 24.11
  • 3.08
  • 0.043
  • ND
No records found.
No records found.
No records found.
No records found.
  • 156
No records found.
  • ND
  • 0.113
  • -3.24
  • -2.16
  • -2.55
Input
  • 0.052
  • 0.00143
  • 0.0000782
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0152
  • 0
  • 0
  • 0.0000515
  • 0.000162
  • 0.0000143
  • 0.0696
Input
  • 0.0378
  • 0.0000181
  • 5.08E-7
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0000882
  • 0
  • 0
  • 6.52E-7
  • 0.00000857
  • 4.29E-7
  • -0.00117
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.0135
  • 0.000419
  • -0.0000596
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0479
  • 0
  • 0
  • 0.0000152
  • 0.000229
  • -0.0000477
  • -0.000334
Output
  • 0.131
  • 0.00543
  • 0.00103
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.38
  • 0
  • 0
  • 0.000177
  • 0.00378
  • 0.00112
  • -0.0178
Output
  • 1.94
  • 0.102
  • 0.167
  • 0
  • 0
  • 0
  • 0
  • 0
  • 24.4
  • 0
  • 0
  • 0.00355
  • 0.101
  • 0.191
  • -0.846
Output
  • 0.000101
  • 6.19E-7
  • 1.53E-7
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.000172
  • 0
  • 0
  • 3.04E-8
  • 4.08E-7
  • 7.84E-9
  • -4.46E-7
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.000054
  • 0
  • 0.109
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.274
  • 0
  • 0
Output
  • 0.0116
  • 0
  • 3.84E-21
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.119
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.799
  • 0
  • 0
Output
  • 0
  • 0
  • 0.0693
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.46
  • 0
  • 0

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
  • 24.1
  • 3.08
  • 0.152
  • 0
  • 0
  • 0
  • 0
  • 0
  • 156
  • 0
  • 0
  • 0.113
  • 0.197
  • 0.0207
  • -2.54
  • 0.00000574
  • 7.27E-7
  • 9.7E-8
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0000105
  • 0
  • 0
  • 2.64E-8
  • 1.42E-7
  • 5.44E-9
  • -6.39E-9
  • 0.007
  • 0.000456
  • 0.0000452
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0729
  • 0
  • 0
  • 0.000026
  • 0.000107
  • 0.0000174
  • -0.00179
  • 2.67E-8
  • 4.35E-9
  • 1.45E-10
  • 0
  • 0
  • 0
  • 0
  • 0
  • 7.02E-8
  • 0
  • 0
  • 1.41E-10
  • 1.4E-10
  • 3.31E-11
  • -5.92E-10
  • 0.000329
  • 0.0000147
  • 0.0000349
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00505
  • 0
  • 0
  • 5.74E-7
  • 0.00000697
  • 2.41E-7
  • -0.00014
  • 0.00158
  • 0.00011
  • 0.0000588
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0151
  • 0
  • 0
  • 0.00000861
  • 0.0000369
  • 0.0000664
  • -0.000364
  • 0.016
  • 0.00119
  • 0.000135
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.156
  • 0
  • 0
  • 0.0000937
  • 0.000311
  • 0.0000819
  • -0.00358
  • -0.274
  • 0.0000439
  • 0.277
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00465
  • 0
  • 0
  • 0.00000167
  • -0.000403
  • 0.000183
  • -0.148
  • 1.66
  • 0.219
  • 0.0137
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.44E+11
  • 0
  • 0
  • 0.00808
  • 0.157
  • 0.0673
  • -0.266
  • 0.00244
  • 0.0000786
  • 0.00000494
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0106
  • 0
  • 0
  • 0.00000316
  • 0.000029
  • 7.44E-7
  • 0.000194
  • 1.388
  • 0.2191
  • 0.2907
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.44E+11
  • 0
  • 0
  • 0.008085
  • 0.1566
  • 0.06748
  • -0.4138
  • 0.00604
  • 0.000758
  • 0.0000498
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0437
  • 0
  • 0
  • 0.0000388
  • 0.0000839
  • 0.0000222
  • -0.00101
  • 0.21
  • 0.0153
  • 0.0305
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.85
  • 0
  • 0
  • 0.000545
  • 0.0124
  • 0.00427
  • 0.0422

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Incidence of disease due to PM emissions (PM) 2
  • 8.8E-8
  • 1.61E-8
  • 4.76E-10
  • 0
  • 0
  • 0
  • 0
  • 0
  • 7.71E-7
  • 0
  • 0
  • 6.41E-10
  • 1.1E-9
  • 1.35E-10
  • -2.64E-8
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 17.6
  • 0.409
  • 0.151
  • 0
  • 0
  • 0
  • 0
  • 0
  • 34.3
  • 0
  • 0
  • 0.0161
  • 0.733
  • 0.222
  • 1.42
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 9.82E-10
  • 3.67E-11
  • 2.85E-11
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.6E-9
  • 0
  • 0
  • 1.37E-12
  • 1.99E-11
  • 5.81E-12
  • -3.41E-11
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 1.09E-8
  • 1.95E-9
  • 2.32E-10
  • 0
  • 0
  • 0
  • 0
  • 0
  • 8.37E-8
  • 0
  • 0
  • 7.12E-11
  • 8.24E-10
  • 2.58E-10
  • -1.3E-9
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.131
  • 0.00396
  • 0.000617
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.7
  • 0
  • 0
  • 0.000123
  • 0.00167
  • 0.0000312
  • -0.00292
Soil quality index (SQP) 2
  • 37.5
  • 1.87
  • 0.0478
  • 0
  • 0
  • 0
  • 0
  • 0
  • 26.2
  • 0
  • 0
  • 0.0688
  • 0.0835
  • 0.0224
  • -13.1