Process Data set: Aludec - Laminated duct (en) en

Key Data Set Information
Reference year 2026
Name
Aludec - Laminated duct
Technical purpose of product or process Aludec® ducts are high-quality, flexible laminate ducts designed for use in a wide range of HVAC applications. They are constructed from multiple layers of aluminium and polyester, reinforced with a high-tensile carbon steel spiral helix embedded between the layers for added strength and flexibility. This unique multi-layer design ensures complete overlap of the aluminium and polyester films, providing excellent mechanical performance and durability. Aludec ducts are compatible with both round and oval connectors, allowing for easy and secure installation without the need for special tools or sealing components. The fire resistance of Aludec® ducts complies with all relevant international standards, ensuring safe operation in standard building ventilation systems. These ducts are primarily intended for use in general air supply and air conditioning systems where no special mechanical or thermal requirements are imposed. Aludec® products are fully compliant with the requirements outlined in EN 13180: Ventilation for Buildings – Ductwork – Dimensions and Mechanical Requirements for Flexible Ducts, and carry Eurovent certification, confirming their quality and performance. This Environmental Product Declaration (EPD) is based on the Aludec A23 model, which represents the average product within the Aludec range. It covers the entire spectrum of products—from Aludec A11 (best-case scenario) to Aludec 112 (worst-case scenario). For detailed technical data, certifications, and additional documentation, please visit:www.decinternational.com
Classification
Class name : Hierarchy level
  • One Click LCA: Material / Building Technology / Ventilation Ducts Channels
General comment on data set Aludec® ducts are high-quality, flexible laminate ducts designed for use in a wide range of HVAC applications. They are constructed from multiple layers of aluminium and polyester, reinforced with a high-tensile carbon steel spiral helix embedded between the layers for added strength and flexibility. This unique multi-layer design ensures complete overlap of the aluminium and polyester films, providing excellent mechanical performance and durability. Aludec ducts are compatible with both round and oval connectors, allowing for easy and secure installation without the need for special tools or sealing components. The fire resistance of Aludec® ducts complies with all relevant international standards, ensuring safe operation in standard building ventilation systems. These ducts are primarily intended for use in general air supply and air conditioning systems where no special mechanical or thermal requirements are imposed. Aludec® products are fully compliant with the requirements outlined in EN 13180: Ventilation for Buildings – Ductwork – Dimensions and Mechanical Requirements for Flexible Ducts, and carry Eurovent certification, confirming their quality and performance. This Environmental Product Declaration (EPD) is based on the Aludec A23 model, which represents the average product within the Aludec range. It covers the entire spectrum of products—from Aludec A11 (best-case scenario) to Aludec 112 (worst-case scenario). For detailed technical data, certifications, and additional documentation, please visit:www.decinternational.com
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Material properties of the reference flow
    • linear density: 0.127 kg/m
    • weight per piece: 0.127 kg
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.0 kg
Time representativeness
Data set valid until 2031
Technological representativeness
Technology description including background system Aludec® ducts are high-quality, flexible laminate ducts designed for use in a wide range of HVAC applications. They are constructed from multiple layers of aluminium and polyester, reinforced with a high-tensile carbon steel spiral helix embedded between the layers for added strength and flexibility. This unique multi-layer design ensures complete overlap of the aluminium and polyester films, providing excellent mechanical performance and durability. Aludec ducts are compatible with both round and oval connectors, allowing for easy and secure installation without the need for special tools or sealing components. The fire resistance of Aludec® ducts complies with all relevant international standards, ensuring safe operation in standard building ventilation systems. These ducts are primarily intended for use in general air supply and air conditioning systems where no special mechanical or thermal requirements are imposed. Aludec® products are fully compliant with the requirements outlined in EN 13180: Ventilation for Buildings – Ductwork – Dimensions and Mechanical Requirements for Flexible Ducts, and carry Eurovent certification, confirming their quality and performance. This Environmental Product Declaration (EPD) is based on the Aludec A23 model, which represents the average product within the Aludec range. It covers the entire spectrum of products—from Aludec A11 (best-case scenario) to Aludec 112 (worst-case scenario). For detailed technical data, certifications, and additional documentation, please visit:www.decinternational.com

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 1.06
  • 0.0481
  • -0.342
  • ND
  • 0
  • 0.000831
  • 0.0053
  • 0.0000947
  • -0.137
Input
  • 0.284
  • 0
  • -0.284
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0.0413
Input
  • 1.344
  • 0.0481
  • -0.626
  • ND
  • ND
  • 0.000831
  • 0.0053
  • 0.0000947
  • -0.0957
Input
  • 10.2
  • 1.99
  • -0.499
  • ND
  • 0
  • 0.0606
  • -0.473
  • -0.358
  • -2.26
Input
  • 1.43
  • 0
  • -0.553
  • ND
  • 0
  • 0
  • -0.533
  • -0.344
  • 0.396
Input
  • 11.63
  • 1.99
  • -1.052
  • ND
  • ND
  • 0.0606
  • -1.006
  • -0.702
  • -1.864
Input
  • 0.0347
  • 0.00109
  • 0.00003
  • ND
  • 0
  • 0.0000269
  • 0.0000513
  • 0.0000018
  • 0.0848
Input
  • 0.00668
  • 0.0000117
  • 2.33E-7
  • ND
  • 0
  • 3.42E-7
  • 0.00000168
  • 3.22E-8
  • -0.00000979
Input
  • 0
  • 0
  • 0
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.00797
  • 0.000314
  • -0.0000217
  • ND
  • 0
  • 0.00000826
  • 0.0000203
  • -0.0000449
  • -0.000944
Output
  • 0.191
  • 0.00309
  • 0.000275
  • ND
  • 0
  • 0.000105
  • 0.000451
  • 0.0000156
  • -0.0432
Output
  • 3.58
  • 0.0751
  • 0.0521
  • ND
  • 0
  • 0.00196
  • 0.0167
  • 0.0638
  • -0.529
Output
  • 0.0000131
  • 9.32E-7
  • 1.66E-8
  • ND
  • 0
  • 1.22E-8
  • 5.53E-8
  • 1.54E-9
  • -5.72E-7
Output
  • 0
  • 0
  • 0
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.00612
  • 0
  • 0.0183
  • ND
  • 0
  • 0
  • 0.0949
  • 0
  • -6.99E-12
Output
  • 0
  • 0
  • 0
  • ND
  • 0
  • 0
  • 0
  • 0
  • -3.65E-20
Output
  • 0.00162
  • 0
  • 0.0972
  • ND
  • 0
  • 0
  • 0.136
  • 0
  • 0
Output
  • 0.000935
  • 0
  • 0.0563
  • ND
  • 0
  • 0
  • 0.0788
  • 0
  • 0

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
  • 11.8
  • 1.99
  • 0.0154
  • ND
  • 0
  • 0.0606
  • 0.0326
  • 0.0054
  • -2.24
  • 0.0000831
  • 6.35E-7
  • 7.63E-9
  • ND
  • 0
  • 1.36E-8
  • 1.49E-7
  • 5.55E-10
  • -0.00000144
  • 0.00555
  • 0.000288
  • 0.0000075
  • ND
  • 0
  • 0.0000144
  • 0.0000294
  • 0.00000172
  • -0.00244
  • 1.07E-8
  • 2.82E-9
  • 1.77E-11
  • ND
  • 0
  • 6.07E-11
  • 3.27E-11
  • 6.2E-12
  • -2.01E-9
  • 0.000466
  • 0.0000113
  • 3.08E-7
  • ND
  • 0
  • 3.34E-7
  • 0.00000143
  • 2.91E-8
  • -0.0000838
  • 0.00103
  • 0.0000633
  • 0.00000762
  • ND
  • 0
  • 0.00000467
  • 0.00000784
  • 0.0000121
  • -0.000427
  • 0.011
  • 0.000683
  • 0.0000296
  • ND
  • 0
  • 0.0000508
  • 0.000083
  • 0.00000691
  • -0.00468
  • -0.0305
  • 0.000032
  • 0.0328
  • ND
  • 0
  • 9.45E-7
  • -0.00000568
  • -8.44E-7
  • -0.00493
  • 0.924
  • 0.143
  • 0.0167
  • ND
  • 0
  • 0.00429
  • 0.029
  • 0.00117
  • -0.459
  • 0.00254
  • 0.0000576
  • 0.00000134
  • ND
  • 0
  • 0.0000019
  • 0.00000309
  • 2.16E-7
  • -0.00147
  • 0.896
  • 0.1431
  • 0.0495
  • ND
  • 0
  • 0.004293
  • 0.029
  • 0.001169
  • -0.4654
  • 0.00365
  • 0.000457
  • 0.00000937
  • ND
  • 0
  • 0.0000203
  • 0.0000237
  • 0.00000259
  • -0.0047
  • 0.326
  • 0.0114
  • 0.00071
  • ND
  • 0
  • 0.000286
  • 0.00118
  • 0.0000473
  • -0.307

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Incidence of disease due to PM emissions (PM) 2
  • 6.33E-8
  • 7.53E-9
  • 1.03E-10
  • ND
  • 0
  • 3.61E-10
  • 3.74E-10
  • 3.68E-11
  • -1.82E-8
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 8.03
  • 0.353
  • 0.0228
  • ND
  • 0
  • 0.00934
  • 0.0235
  • 0.53
  • -0.969
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 7.11E-10
  • 2.56E-11
  • 1.34E-12
  • ND
  • 0
  • 7.24E-13
  • 2.96E-12
  • 1.51E-13
  • -2.91E-9
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 1.47E-8
  • 1.19E-9
  • 5.81E-11
  • ND
  • 0
  • 3.83E-11
  • 1.68E-10
  • 2.86E-11
  • -5.29E-9
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.0521
  • 0.00372
  • 0.0000655
  • ND
  • 0
  • 0.00005
  • 0.000217
  • 0.00000629
  • -0.00397
Soil quality index (SQP) 2
  • 4.93
  • 0.832
  • 0.0156
  • ND
  • 0
  • 0.0423
  • 0.0586
  • 0.0109
  • -4.18