Process Data set: Biddle SR M-200-E Electric air curtain (en) en

Key Data Set Information
Reference year 2026
Name
Biddle SR M-200-E Electric air curtain
Technical purpose of product or process The SR air curtain has been developed to deliver greater comfort than a conventional air curtain, whilst providing considerable energy savings. The SR does not act as a barrier in the place of an open door, but it reduces the amount of warm air leaving the building and conditions the incoming air to a comfortable temperature. The SR air curtain delivers the right air flow and temperature at the right time automatically, ensuring optimal climate separation and reducing energy loss and offers a unique air damper system to improve efficiency by controlling the outlet velocity. The impressive results achieved by the SR are made possible thanks to a combination of four technologies. The revolutionary patented i-sense infrared technology collects all temperature related data in the doorway. CHIPS technology translates this information into the correct setting, whilst the adaptable discharge width (Controlled Air strength technology) and the patented rectifier technology create the perfect climate separation. The SR can be supplied to suit many heating mediums, with water, electric, a combination of low grade water and electric (Hybrid) and ambient models all being available. The SR is designed for door heights from 2.0 to 4.0 m and is mounted horizontally above door openings in shopping malls, shops, stores, supermarkets and other commercial spaces. This EPD covers multiple models in the electric SR range and is based on the SR M-200-E. This model was chosen as representative model because it's technically the middle of the full range of products and additionally the bestselling product. The EPD is applicable for the following units in F/R/C versions: S-100-E, S-150-E, S-200-E, S-250-E, M-100-E, M-150-E, M-200-E, M-250-E, L-100-E, L-150-E, L-200-E, L-250-E, XL-100-E, XL-150-E, XL-200-E, XL-250-E Please see the annex for more information on variability. The casing is made of zinc plated sheet steel and has an inspection panel in the bottom. The inlet grilles are made of anodised aluminium with fixed fins. The inlet module and the end panels as well as the casing are, as a standard, supplied in silver grey (RAL 9006) or traffic white (RAL 9016). The air curtain is equipped with two or more (depending on type) dual-inlet, vibration free suspended centrifugal fans. The SR Electric is made up of electric heating elements with aluminium fins. The exchanger is controlled by the electronic control unit and is fitted with overload protection. Further information can be found at: www.Biddle.nl
Classification
Class name : Hierarchy level
  • One Click LCA: Material / Building Technology / HVAC
General comment on data set The SR air curtain has been developed to deliver greater comfort than a conventional air curtain, whilst providing considerable energy savings. The SR does not act as a barrier in the place of an open door, but it reduces the amount of warm air leaving the building and conditions the incoming air to a comfortable temperature. The SR air curtain delivers the right air flow and temperature at the right time automatically, ensuring optimal climate separation and reducing energy loss and offers a unique air damper system to improve efficiency by controlling the outlet velocity. The impressive results achieved by the SR are made possible thanks to a combination of four technologies. The revolutionary patented i-sense infrared technology collects all temperature related data in the doorway. CHIPS technology translates this information into the correct setting, whilst the adaptable discharge width (Controlled Air strength technology) and the patented rectifier technology create the perfect climate separation. The SR can be supplied to suit many heating mediums, with water, electric, a combination of low grade water and electric (Hybrid) and ambient models all being available. The SR is designed for door heights from 2.0 to 4.0 m and is mounted horizontally above door openings in shopping malls, shops, stores, supermarkets and other commercial spaces. This EPD covers multiple models in the electric SR range and is based on the SR M-200-E. This model was chosen as representative model because it's technically the middle of the full range of products and additionally the bestselling product. The EPD is applicable for the following units in F/R/C versions: S-100-E, S-150-E, S-200-E, S-250-E, M-100-E, M-150-E, M-200-E, M-250-E, L-100-E, L-150-E, L-200-E, L-250-E, XL-100-E, XL-150-E, XL-200-E, XL-250-E Please see the annex for more information on variability. The casing is made of zinc plated sheet steel and has an inspection panel in the bottom. The inlet grilles are made of anodised aluminium with fixed fins. The inlet module and the end panels as well as the casing are, as a standard, supplied in silver grey (RAL 9006) or traffic white (RAL 9016). The air curtain is equipped with two or more (depending on type) dual-inlet, vibration free suspended centrifugal fans. The SR Electric is made up of electric heating elements with aluminium fins. The exchanger is controlled by the electronic control unit and is fitted with overload protection. Further information can be found at: www.Biddle.nl
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Material properties of the reference flow
    • weight per piece: 107.8 kg
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.0 kg
Time representativeness
Data set valid until 2031
Technological representativeness
Technology description including background system The SR air curtain has been developed to deliver greater comfort than a conventional air curtain, whilst providing considerable energy savings. The SR does not act as a barrier in the place of an open door, but it reduces the amount of warm air leaving the building and conditions the incoming air to a comfortable temperature. The SR air curtain delivers the right air flow and temperature at the right time automatically, ensuring optimal climate separation and reducing energy loss and offers a unique air damper system to improve efficiency by controlling the outlet velocity. The impressive results achieved by the SR are made possible thanks to a combination of four technologies. The revolutionary patented i-sense infrared technology collects all temperature related data in the doorway. CHIPS technology translates this information into the correct setting, whilst the adaptable discharge width (Controlled Air strength technology) and the patented rectifier technology create the perfect climate separation. The SR can be supplied to suit many heating mediums, with water, electric, a combination of low grade water and electric (Hybrid) and ambient models all being available. The SR is designed for door heights from 2.0 to 4.0 m and is mounted horizontally above door openings in shopping malls, shops, stores, supermarkets and other commercial spaces. This EPD covers multiple models in the electric SR range and is based on the SR M-200-E. This model was chosen as representative model because it's technically the middle of the full range of products and additionally the bestselling product. The EPD is applicable for the following units in F/R/C versions: S-100-E, S-150-E, S-200-E, S-250-E, M-100-E, M-150-E, M-200-E, M-250-E, L-100-E, L-150-E, L-200-E, L-250-E, XL-100-E, XL-150-E, XL-200-E, XL-250-E Please see the annex for more information on variability. The casing is made of zinc plated sheet steel and has an inspection panel in the bottom. The inlet grilles are made of anodised aluminium with fixed fins. The inlet module and the end panels as well as the casing are, as a standard, supplied in silver grey (RAL 9006) or traffic white (RAL 9016). The air curtain is equipped with two or more (depending on type) dual-inlet, vibration free suspended centrifugal fans. The SR Electric is made up of electric heating elements with aluminium fins. The exchanger is controlled by the electronic control unit and is fitted with overload protection. Further information can be found at: www.Biddle.nl

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 2.75E+3
  • 4.28
  • -507
  • 0
  • 0
  • 0
  • 0
  • 0
  • 3.74E+5
  • 0
  • 0
  • 0.942
  • 6.44
  • 0.127
  • -668
Input
  • 489
  • 0
  • -489
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 98.8
Input
  • 3239
  • 4.28
  • -996
  • ND
No records found.
No records found.
No records found.
No records found.
  • 3.74E+5
No records found.
  • ND
  • 0.942
  • 6.44
  • 0.127
  • -569.2
Input
  • 1.96E+4
  • 245
  • 15.5
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.36E+6
  • 0
  • 0
  • 54
  • 42.2
  • -1E+2
  • -2.37E+3
Input
  • 24.7
  • 0
  • -24.7
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 6.45
Input
  • 1.962E+4
  • 245
  • -9.2
  • ND
No records found.
No records found.
No records found.
No records found.
  • 1.36E+6
No records found.
  • ND
  • 54
  • 42.2
  • -1E+2
  • -2364
Input
  • 62.9
  • 0.114
  • 0.0135
  • 0
  • 0
  • 0
  • 0
  • 0
  • 225
  • 0
  • 0
  • 0.025
  • 0.0326
  • 0.00221
  • 57.6
Input
  • 13.4
  • 0.00143
  • 0.000144
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.8
  • 0
  • 0
  • 0.000317
  • 0.00209
  • 0.0000385
  • -0.0168
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 17.2
  • 0.0333
  • -0.0323
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.18E+3
  • 0
  • 0
  • 0.00735
  • 0.0208
  • -0.0289
  • -5.8
Output
  • 2.4E+2
  • 0.356
  • 0.131
  • 0
  • 0
  • 0
  • 0
  • 0
  • 3.45E+3
  • 0
  • 0
  • 0.0787
  • 0.312
  • 0.0243
  • -56.6
Output
  • 8.12E+3
  • 7.5
  • 60.2
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.67E+5
  • 0
  • 0
  • 1.66
  • 8.48
  • 46.3
  • 313
Output
  • 0.0728
  • 0.0000783
  • 0.0000138
  • 0
  • 0
  • 0
  • 0
  • 0
  • 9.66
  • 0
  • 0
  • 0.0000172
  • 0.0000719
  • 0.00000209
  • -0.00685
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 26.7
  • 0
  • 17
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 74.1
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 42.3
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 18.5
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
  • 1.96E+4
  • 245
  • 15.5
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.36E+6
  • 0
  • 0
  • 54
  • 42.2
  • 7.04
  • -2.37E+3
  • 0.383
  • 0.0000578
  • 0.00000506
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.79
  • 0
  • 0
  • 0.0000128
  • 0.000132
  • 7.14E-7
  • -0.0055
  • 20.6
  • 0.0382
  • 0.00618
  • 0
  • 0
  • 0
  • 0
  • 0
  • 344
  • 0
  • 0
  • 0.00805
  • 0.0293
  • 0.0022
  • -1.31
  • 0.0000521
  • 3.46E-7
  • 1.77E-8
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00108
  • 0
  • 0
  • 7.6E-8
  • 3.18E-8
  • 8.04E-9
  • -0.00000201
  • 1.63
  • 0.00117
  • 0.00031
  • 0
  • 0
  • 0
  • 0
  • 0
  • 54.5
  • 0
  • 0
  • 0.000259
  • 0.00176
  • 0.0000394
  • -0.304
  • 3.32
  • 0.0092
  • 0.00723
  • 0
  • 0
  • 0
  • 0
  • 0
  • 54
  • 0
  • 0
  • 0.00195
  • 0.00621
  • 0.00699
  • -0.239
  • 59.4
  • 0.0994
  • 0.0237
  • 0
  • 0
  • 0
  • 0
  • 0
  • 484
  • 0
  • 0
  • 0.021
  • 0.0693
  • 0.00879
  • -2.95
  • -56.2
  • 0
  • 56.2
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • -11.3
  • 1.56E+3
  • 17.4
  • 1.22
  • 0
  • 0
  • 0
  • 0
  • 0
  • 5.85E+4
  • 0
  • 0
  • 3.84
  • 3.42
  • 0.577
  • -192
  • 3.22
  • 0.00626
  • 0.00148
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.8E+2
  • 0
  • 0
  • 0.00138
  • 0.00513
  • 0.000316
  • -2.32
  • 1507
  • 17.41
  • 57.42
  • 0
  • 0
  • 0
  • 0
  • 0
  • 5.868E+4
  • 0
  • 0
  • 3.841
  • 3.425
  • 0.5773
  • -205.6
  • 6.53
  • 0.0616
  • 0.00803
  • 0
  • 0
  • 0
  • 0
  • 0
  • 159
  • 0
  • 0
  • 0.0133
  • 0.0202
  • 0.00305
  • -0.856
  • 697
  • 1.21
  • 0.411
  • 0
  • 0
  • 0
  • 0
  • 0
  • 3.71E+4
  • 0
  • 0
  • 0.268
  • 0.741
  • 0.0748
  • -191

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Incidence of disease due to PM emissions (PM) 2
  • 0.000194
  • 0.00000128
  • 1.04E-7
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00123
  • 0
  • 0
  • 2.83E-7
  • 3.69E-7
  • 4.6E-8
  • -0.0000182
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 4.24E+4
  • 32.5
  • 15.4
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.08E+5
  • 0
  • 0
  • 7.2
  • 18.6
  • 1.03E+3
  • -2.84E+3
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 0.00000171
  • 2.92E-9
  • 6.89E-10
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0000198
  • 0
  • 0
  • 6.44E-10
  • 2.1E-9
  • 1.7E-10
  • -1.58E-7
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 0.0000709
  • 1.55E-7
  • 3.63E-8
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00103
  • 0
  • 0
  • 3.41E-8
  • 1.48E-7
  • 3.06E-8
  • 0.00000136
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 177
  • 0.315
  • 0.0548
  • 0
  • 0
  • 0
  • 0
  • 0
  • 3.76E+4
  • 0
  • 0
  • 0.0692
  • 0.292
  • 0.00855
  • -25.8
Soil quality index (SQP) 2
  • 1.15E+4
  • 147
  • 14.7
  • 0
  • 0
  • 0
  • 0
  • 0
  • 3.03E+5
  • 0
  • 0
  • 32.6
  • 50.7
  • 13
  • -626