Close Go back Collapse all sections
Process Data set: BEAM 13W (en) en

Key Data Set Information
Reference year 2026
Name
BEAM 13W
Technical purpose of product or process BEAM 13W 930 Spotlight is a 13 W indoor LED track-mounted luminaire uniquely identified by its model designation and 930 light specification (3000 K, CRI ≥ 90). The product consists of a powder-coated aluminium housing, integrated COB LED module, 36° lens optic, and track adapter. It delivers 3000 K correlated colour temperature with Ra ≥ 90 and is designed for professional accent and general indoor lighting applications. Lumen maintenance is specified as L88 at 50,000 h, L84 at 75,000 h, and L80 at 100,000 h (declared RSL 100,000 h under normal indoor conditions). The product is manufactured and tested in accordance with EN 60598 and other applicable European standards, consistent with the associated project report under EN 15804+A2.
Classification
Class name : Hierarchy level
  • One Click LCA: Material / Building Technology / Lighting
General comment on data set BEAM 13W 930 Spotlight is a 13 W indoor LED track-mounted luminaire uniquely identified by its model designation and 930 light specification (3000 K, CRI ≥ 90). The product consists of a powder-coated aluminium housing, integrated COB LED module, 36° lens optic, and track adapter. It delivers 3000 K correlated colour temperature with Ra ≥ 90 and is designed for professional accent and general indoor lighting applications. Lumen maintenance is specified as L88 at 50,000 h, L84 at 75,000 h, and L80 at 100,000 h (declared RSL 100,000 h under normal indoor conditions). The product is manufactured and tested in accordance with EN 60598 and other applicable European standards, consistent with the associated project report under EN 15804+A2.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Material properties of the reference flow
    • weight per piece: 0.44 kg
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 1.077 kg
Time representativeness
Data set valid until 2031
Technological representativeness
Technology description including background system BEAM 13W 930 Spotlight is a 13 W indoor LED track-mounted luminaire uniquely identified by its model designation and 930 light specification (3000 K, CRI ≥ 90). The product consists of a powder-coated aluminium housing, integrated COB LED module, 36° lens optic, and track adapter. It delivers 3000 K correlated colour temperature with Ra ≥ 90 and is designed for professional accent and general indoor lighting applications. Lumen maintenance is specified as L88 at 50,000 h, L84 at 75,000 h, and L80 at 100,000 h (declared RSL 100,000 h under normal indoor conditions). The product is manufactured and tested in accordance with EN 60598 and other applicable European standards, consistent with the associated project report under EN 15804+A2.

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Production
A1-A3
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 9.809
  • 43.38
  • 0.1831
  • 33.39
  • 0.003157
  • -32.84
  • ND
  • 1775
  • ND
  • ND
  • 0.02523
  • 0.001367
  • -1.42
Input
  • 0
  • 34.65
  • 0
  • 34.65
  • 0
  • -34.65
  • ND
  • 0
  • ND
  • ND
  • 0
  • 0
  • 0
Input
  • 9.809
  • 78.03
  • 0.1831
  • 68.04
  • 0.003157
  • -67.49
  • ND
  • 1775
  • ND
  • ND
  • 0.02523
  • 0.001367
  • -1.42
Input
  • 133.2
  • 166.4
  • 13.36
  • 19.9
  • 0.2304
  • 0.5118
  • ND
  • 3.41E+3
  • ND
  • ND
  • -0.6023
  • -0.7194
  • 3.913
Input
  • 3.841
  • 6.015
  • 0
  • 2.174
  • 0
  • -2.174
  • ND
  • 0
  • ND
  • ND
  • -1.535
  • -2.306
  • 0
Input
  • 137
  • 172.5
  • 13.36
  • 22.08
  • 0.2304
  • -1.662
  • ND
  • 3.41E+3
  • ND
  • ND
  • -2.137
  • -3.026
  • 3.913
Input
  • 0.02812
  • 0.02812
No records found.
No records found.
  • ND
  • ND
  • ND
No records found.
  • ND
  • ND
  • ND
  • ND
  • ND
Input
  • 0.002452
  • 0.8823
  • 0.00007222
  • 0.8798
  • 0.000001246
  • 0.000002752
  • ND
  • 0.01589
  • ND
  • ND
  • 0.000008352
  • 8.96E-7
  • 0.00003074
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • ND
  • 0
  • ND
  • ND
  • 0
  • 0
  • 0
Input
  • 0.06425
  • 0.07801
  • 0.001975
  • 0.01179
  • 0.00003406
  • -0.00341
  • ND
  • 1.929
  • ND
  • ND
  • 0.0001409
  • -0.0001192
  • -0.002356
Output
  • 1.751
  • 1.869
  • 0.02263
  • 0.09629
  • 0.0003903
  • 0.006609
  • ND
  • 5.356
  • ND
  • ND
  • 0.002125
  • 0.02828
  • 0.08998
Output
  • 36.1
  • 38.24
  • 0.4188
  • 1.725
  • 0.007223
  • 5.857
  • ND
  • 158
  • ND
  • ND
  • 0.0562
  • 0.3878
  • 4.084
Output
  • 0.0002171
  • 0.000246
  • 0.000002848
  • 0.00002603
  • 4.912E-8
  • 0.000001056
  • ND
  • 0.0466
  • ND
  • ND
  • 3.041E-7
  • 1.974E-8
  • 0.000006662
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • ND
  • 0
  • ND
  • ND
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.9319
  • ND
  • 0
  • ND
  • ND
  • 0.2245
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • ND
  • 0
  • ND
  • ND
  • 0
  • 0
  • 0
Output
No records found.
  • ND
No records found.
No records found.
  • ND
  • 1.758
  • ND
No records found.
  • ND
  • ND
  • 0.103
  • ND
  • ND
Output
No records found.
  • ND
No records found.
No records found.
  • ND
  • 2.414
  • ND
No records found.
  • ND
  • ND
  • 0.1416
  • ND
  • ND

IndicatorUnit Raw material supply
A1
Production
A1-A3
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
  • 137
  • 172.4
  • 13.36
  • 22.04
  • 0.2304
  • 0.5118
  • ND
  • 3.41E+3
  • ND
  • ND
  • 0.1775
  • 0.06033
  • 3.923
  • 0.001089
  • 0.001098
  • 0.000002568
  • 0.000006077
  • 4.429E-8
  • 9.485E-8
  • ND
  • 0.003473
  • ND
  • ND
  • 4.329E-7
  • 1.072E-8
  • 9.086E-7
  • 0.09099
  • 0.1165
  • 0.003138
  • 0.02232
  • 0.00005413
  • 0.0002538
  • ND
  • 0.5001
  • ND
  • ND
  • 0.0001182
  • 0.00002664
  • 0.001525
  • 2.14E-7
  • 2.509E-7
  • 1.359E-8
  • 2.336E-8
  • 2.344E-10
  • 5.455E-10
  • ND
  • 0.000003295
  • ND
  • ND
  • 1.354E-10
  • 7.105E-11
  • 2.424E-9
  • 0.007718
  • 0.00813
  • 0.00007166
  • 0.0003405
  • 0.000001236
  • 0.00001966
  • ND
  • 0.0304
  • ND
  • ND
  • 0.000006893
  • 5.852E-7
  • 0.0001455
  • 0.01393
  • 0.02087
  • 0.001031
  • 0.005914
  • 0.00001779
  • 0.0004619
  • ND
  • 0.09156
  • ND
  • ND
  • 0.00002873
  • 0.00003396
  • 0.0003686
  • 0.1442
  • 0.2185
  • 0.01122
  • 0.06306
  • 0.0001935
  • 0.001079
  • ND
  • 1.111
  • ND
  • ND
  • 0.000302
  • 0.0001152
  • 0.003199
  • 0.03555
  • -3.913
  • 0.0002085
  • -3.949
  • 0.000003596
  • 3.876
  • ND
  • 1.099
  • ND
  • ND
  • -0.00003663
  • -0.000006333
  • -1.511
  • 11.33
  • 13.85
  • 0.9204
  • 1.598
  • 0.01588
  • 0.03324
  • ND
  • 58.35
  • ND
  • ND
  • 0.06465
  • 0.0296
  • 0.3401
  • 0.01173
  • 0.02012
  • 0.0004118
  • 0.007982
  • 0.000007103
  • 0.00002946
  • ND
  • 0.7923
  • ND
  • ND
  • 0.00002199
  • 0.000004854
  • 0.0007217
  • 11.38
  • 9.955
  • 0.921
  • -2.343
  • 0.01589
  • 3.909
  • ND
  • 60.24
  • ND
  • ND
  • 0.06464
  • 0.0296
  • -1.17
  • 0.05064
  • 0.07383
  • 0.004626
  • 0.01857
  • 0.00007979
  • 0.0003328
  • ND
  • 0.2804
  • ND
  • ND
  • 0.00008548
  • 0.000035
  • 0.001142
  • 2.528
  • 3.133
  • 0.06598
  • 0.5391
  • 0.001138
  • 0.03251
  • ND
  • 82.24
  • ND
  • ND
  • 0.006344
  • 0.002373
  • 0.2078

IndicatorUnit Raw material supply
A1
Production
A1-A3
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Incidence of disease due to PM emissions (PM) 2
  • 6.287E-7
  • 8.854E-7
  • 9.216E-8
  • 1.646E-7
  • 1.59E-9
  • 3.538E-9
  • ND
  • 0.000004703
  • ND
  • ND
  • 1.35E-9
  • 4.687E-10
  • 3.287E-8
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 138.9
  • 149.3
  • 1.889
  • 8.43
  • 0.03259
  • 0.8541
  • ND
  • 4628
  • ND
  • ND
  • 0.1673
  • 6.569
  • 2.965
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 6.354E-9
  • 1.179E-8
  • 1.519E-10
  • 5.28E-9
  • 2.62E-12
  • 3.165E-11
  • ND
  • 5.315E-8
  • ND
  • ND
  • 1.184E-11
  • 1.383E-11
  • 6.843E-10
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 2.114E-7
  • 2.339E-7
  • 8.648E-9
  • 1.385E-8
  • 1.492E-10
  • 2.077E-9
  • ND
  • 0.000003075
  • ND
  • ND
  • 6.959E-10
  • 6.875E-10
  • 2.002E-8
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.8878
  • 1.015
  • 0.01163
  • 0.1154
  • 0.0002007
  • 0.004127
  • ND
  • 218
  • ND
  • ND
  • 0.001241
  • 0.00008014
  • 0.02656
Soil quality index (SQP) 2
  • 36.8
  • 540.3
  • 13.45
  • 490.1
  • 0.232
  • 0.6501
  • ND
  • 2338
  • ND
  • ND
  • 0.1693
  • 0.09204
  • 17.4