Close Go back Collapse all sections
Process Data set: Air Purifier Units With Chemical Filters (en) en

Key Data Set Information
Reference year 2026
Name
Air Purifier Units With Chemical Filters
Technical purpose of product or process Clean air is important for the well-being of sensitive equipment in the premises, in addition to people’s well-being. Air pollutants and the resulting corrosion cause malfunctions in equipment and systems. System failure can even lead to the shutdown of the entire production process, which can result in significant financial losses. Our air purifiers are designed to remove dust, odours, gases and particles from the air in very demanding conditions to protect electronics and electrical equipment from malfunctions. Climecon’s broad selection of air filtration products helps in creating the best possible indoor air in various locations. The reliable technology we use has so far been used to implement several hundred air purification systems in data centres, server rooms and electrical rooms in the process industry, among other places. Climecon designs and manufacturers customized air purifiers that utilize so called dry scrubbing purifying technique. The materials of filtering components and the quality and quantity of filter media is chosen considering the composition and concentration of the impurities in the air. This environmental product declaration covers the following products: • UltraCarbon is a chemical air purifier for professional kitchens, restaurants and food industry. UltraCarbon air purifier is a compact solution for efficient purification of both gaseous contaminants and particles in the air. • PSA air purifier unit is perfect for purifying supply air when background levels are high and excellent purity is required. PSA is typically used in industrial applications for protecting electronics and electrical devices from corrosion caused by the surrounding air. It is also perfect for purifying compressor intake air and eliminating odours in wastewater systems. PSA is modularly constructed and allows the building of one or more chemical filtering stages. • KPC is a chemical air purifier that cleans particles, odours, exhaust fumes and urban air. It is a compact solution for the efficient purification of both gaseous contaminants and particles in the air. All the air purifiers come in various sizes, and can be modified according to customer's needs. The type and strength of used chemicals is also adapted to the designed use. The devices use activated carbon and potassium permanganate mix to remove particles. This EPD study was conducted by using an average weight of an air purifier as a reference product. The EPD includes only the air purifier unit without the chemicals.
Classification
Class name : Hierarchy level
  • One Click LCA: Material / Building Technology / HVAC
General comment on data set Clean air is important for the well-being of sensitive equipment in the premises, in addition to people’s well-being. Air pollutants and the resulting corrosion cause malfunctions in equipment and systems. System failure can even lead to the shutdown of the entire production process, which can result in significant financial losses. Our air purifiers are designed to remove dust, odours, gases and particles from the air in very demanding conditions to protect electronics and electrical equipment from malfunctions. Climecon’s broad selection of air filtration products helps in creating the best possible indoor air in various locations. The reliable technology we use has so far been used to implement several hundred air purification systems in data centres, server rooms and electrical rooms in the process industry, among other places. Climecon designs and manufacturers customized air purifiers that utilize so called dry scrubbing purifying technique. The materials of filtering components and the quality and quantity of filter media is chosen considering the composition and concentration of the impurities in the air. This environmental product declaration covers the following products: • UltraCarbon is a chemical air purifier for professional kitchens, restaurants and food industry. UltraCarbon air purifier is a compact solution for efficient purification of both gaseous contaminants and particles in the air. • PSA air purifier unit is perfect for purifying supply air when background levels are high and excellent purity is required. PSA is typically used in industrial applications for protecting electronics and electrical devices from corrosion caused by the surrounding air. It is also perfect for purifying compressor intake air and eliminating odours in wastewater systems. PSA is modularly constructed and allows the building of one or more chemical filtering stages. • KPC is a chemical air purifier that cleans particles, odours, exhaust fumes and urban air. It is a compact solution for the efficient purification of both gaseous contaminants and particles in the air. All the air purifiers come in various sizes, and can be modified according to customer's needs. The type and strength of used chemicals is also adapted to the designed use. The devices use activated carbon and potassium permanganate mix to remove particles. This EPD study was conducted by using an average weight of an air purifier as a reference product. The EPD includes only the air purifier unit without the chemicals.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Material properties of the reference flow
    • weight per piece: 1.0 kg
    • gross density: 1.75E-4 kg/m^3
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.0 kg
Time representativeness
Data set valid until 2031
Technological representativeness
Technology description including background system Clean air is important for the well-being of sensitive equipment in the premises, in addition to people’s well-being. Air pollutants and the resulting corrosion cause malfunctions in equipment and systems. System failure can even lead to the shutdown of the entire production process, which can result in significant financial losses. Our air purifiers are designed to remove dust, odours, gases and particles from the air in very demanding conditions to protect electronics and electrical equipment from malfunctions. Climecon’s broad selection of air filtration products helps in creating the best possible indoor air in various locations. The reliable technology we use has so far been used to implement several hundred air purification systems in data centres, server rooms and electrical rooms in the process industry, among other places. Climecon designs and manufacturers customized air purifiers that utilize so called dry scrubbing purifying technique. The materials of filtering components and the quality and quantity of filter media is chosen considering the composition and concentration of the impurities in the air. This environmental product declaration covers the following products: • UltraCarbon is a chemical air purifier for professional kitchens, restaurants and food industry. UltraCarbon air purifier is a compact solution for efficient purification of both gaseous contaminants and particles in the air. • PSA air purifier unit is perfect for purifying supply air when background levels are high and excellent purity is required. PSA is typically used in industrial applications for protecting electronics and electrical devices from corrosion caused by the surrounding air. It is also perfect for purifying compressor intake air and eliminating odours in wastewater systems. PSA is modularly constructed and allows the building of one or more chemical filtering stages. • KPC is a chemical air purifier that cleans particles, odours, exhaust fumes and urban air. It is a compact solution for the efficient purification of both gaseous contaminants and particles in the air. All the air purifiers come in various sizes, and can be modified according to customer's needs. The type and strength of used chemicals is also adapted to the designed use. The devices use activated carbon and potassium permanganate mix to remove particles. This EPD study was conducted by using an average weight of an air purifier as a reference product. The EPD includes only the air purifier unit without the chemicals.

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 30.1
  • 0.00275
  • -3.68
  • ND
  • 0.000299
  • 0.000823
  • 0.0382
  • 0.000281
  • -1.44
Input
  • 5.87
  • 0
  • -5.87
  • ND
  • 0
  • 0
  • 0
  • 0
  • -5.75
Input
  • 35.97
  • 0.00275
  • -9.55
  • ND
  • 0.000299
  • 0.000823
  • 0.0382
  • 0.000281
  • -7.19
Input
  • 98.3
  • 0.201
  • 0.0304
  • ND
  • 0.0472
  • 0.0601
  • -2.49
  • -0.425
  • -25.4
Input
  • 12.3
  • 0
  • -0.0892
  • ND
  • 0
  • 0
  • -10.5
  • -1.72
  • -1.45
Input
  • 110.6
  • 0.201
  • -0.0588
  • ND
  • 0.0472
  • 0.0601
  • -12.99
  • -2.145
  • -26.85
Input
  • 0.417
  • 0.0000855
  • 0.0000919
  • ND
  • 0.0000196
  • 0.0000256
  • 0.000277
  • 0.00000641
  • 0.628
Input
  • 0.0397
  • 0.00000109
  • 3.79E-7
  • ND
  • 5.12E-8
  • 3.25E-7
  • 0.0000122
  • 1.94E-7
  • -0.0000683
Input
  • 0.182
  • 0
  • 0
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.418
  • 0.0000297
  • 0.000104
  • ND
  • 0.00000312
  • 0.00000888
  • 0.000286
  • 0.0000365
  • -0.0247
Output
  • 2.01
  • 0.00034
  • 0.00156
  • ND
  • 0.0000525
  • 0.000102
  • 0.00424
  • 0.000498
  • -0.384
Output
  • 24.4
  • 0.0063
  • 0.225
  • ND
  • 0.000715
  • 0.00188
  • 0.144
  • 0.0148
  • 7.85
Output
  • 0.022
  • 4.28E-8
  • 8.21E-7
  • ND
  • 5.12E-9
  • 1.28E-8
  • 4.47E-7
  • 3.38E-9
  • -0.0000113
Output
  • 0.00804
  • 0
  • 0
  • ND
  • 0
  • 0
  • 0.231
  • 0
  • 0
Output
  • 8.68
  • 0
  • 0.0094
  • ND
  • 0
  • 0
  • 0.712
  • 0
  • 0
Output
  • 0.00362
  • 0
  • 0.215
  • ND
  • 0
  • 0
  • 0.0109
  • 0
  • 0
Output
  • 0.00407
  • 0
  • 4.19
  • ND
  • 0
  • 0
  • 0.31
  • 0
  • 0
Output
  • 0
  • 0
  • 3.55
  • ND
  • 0
  • 0
  • 0.263
  • 0
  • 0

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
  • 114
  • 0.201
  • 0.118
  • ND
  • 0.0472
  • 0.0601
  • 0.245
  • 0.0109
  • -26.4
  • 0.000287
  • 3.86E-8
  • 2.18E-8
  • ND
  • 1.29E-9
  • 1.15E-8
  • 0.00000105
  • 2.4E-9
  • -0.00000917
  • 0.0445
  • 0.0000472
  • 0.0000466
  • ND
  • 0.0000325
  • 0.0000141
  • 0.000218
  • 0.00000806
  • -0.0054
  • 3.34E-7
  • 2.04E-10
  • 8.8E-11
  • ND
  • 5.52E-11
  • 6.11E-11
  • 2.81E-10
  • 1.68E-11
  • -8.56E-9
  • 0.00166
  • 0.00000108
  • 0.00000203
  • ND
  • 1.04E-7
  • 3.22E-7
  • 0.00001
  • 1.13E-7
  • -0.000408
  • 0.00722
  • 0.0000155
  • 0.0000219
  • ND
  • 0.0000151
  • 0.00000464
  • 0.0000701
  • 0.00000429
  • -0.000833
  • 0.0743
  • 0.000169
  • 0.000213
  • ND
  • 0.000165
  • 0.0000505
  • 0.000646
  • 0.000038
  • -0.0112
  • -0.638
  • 0.00000314
  • 0.961
  • ND
  • 3.68E-7
  • 9.38E-7
  • -0.0000416
  • -0.00000176
  • -0.0159
  • 7.61
  • 0.0138
  • 0.00843
  • ND
  • 0.0036
  • 0.00414
  • 0.187
  • 0.0288
  • -1.35
  • 0.0138
  • 0.00000619
  • 0.0000312
  • ND
  • 3.69E-7
  • 0.00000185
  • 0.0000198
  • 3.44E-7
  • 0.0000335
  • 6.986
  • 0.01381
  • 0.9695
  • ND
  • 0.003601
  • 0.004143
  • 0.187
  • 0.0288
  • -1.366
  • 0.0248
  • 0.0000696
  • 0.000057
  • ND
  • 0.0000493
  • 0.0000208
  • 0.000184
  • 0.0000102
  • -0.00369
  • 3.48
  • 0.000992
  • 0.00899
  • ND
  • 0.000118
  • 0.000297
  • 0.0148
  • 0.0019
  • -0.037

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Incidence of disease due to PM emissions (PM) 2
  • 2.54E-7
  • 1.39E-9
  • 5.93E-10
  • ND
  • 9.25E-10
  • 4.14E-10
  • 2.67E-9
  • 6.86E-11
  • -4.68E-8
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 11.3
  • 0.0284
  • 0.0322
  • ND
  • 0.0026
  • 0.0085
  • 0.465
  • 0.0566
  • 2.26
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 1.98E-9
  • 2.28E-12
  • 7.11E-12
  • ND
  • 3.71E-13
  • 6.83E-13
  • 2.88E-11
  • 2.48E-12
  • 2.05E-11
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 2.57E-8
  • 1.3E-10
  • 4.54E-10
  • ND
  • 5.87E-12
  • 3.89E-11
  • 1.42E-9
  • 8.64E-11
  • 3.87E-8
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.862
  • 0.000175
  • 0.00381
  • ND
  • 0.0000209
  • 0.0000523
  • 0.00174
  • 0.0000134
  • -0.133
Soil quality index (SQP) 2
  • 26.7
  • 0.202
  • 0.052
  • ND
  • 0.0033
  • 0.0605
  • 0.404
  • 0.0121
  • -3.97