Close Go back Collapse all sections
Process Data set: 100% Recycled Aluminium Free Standing Service Pole for Office Installations (en) en

Key Data Set Information
Reference year 2026
Name
100% Recycled Aluminium Free Standing Service Pole for Office Installations
Technical purpose of product or process An effective installation system in office environments is essential for ensuring reliable connectivity, flexibility, and long-term workspace efficiency. As modern interiors evolve toward modular layouts, adaptable cable distribution solutions are needed to support changing technology, varied workstyles, and sustainable building requirements. One of the key solutions within the Wibe Group installation systems portfolio is the free standing aluminium service pole, designed to route power and low voltage services from the ceiling to the workstation in a clean and space efficient manner. The pole is manufactured from 100% recycled aluminium, contributing to a reduced environmental footprint while maintaining structural strength and durability. The stabilizing foot is produced using scrap cast iron, further minimizing embodied carbon compared with components made from primary material. The system consists of a thin round visible pole above desk height, ensuring a discreet appearance suitable for modern office designs. At desk level, a slim service box provides space for power, data, and multimedia wiring devices, enabling efficient cable organization and ergonomic installation. The design accommodates both dedicated Wibe Group wiring devices and standard 80 mm wiring devices, ensuring compatibility with the wall installation trunking system. For ceiling integration, the pole connects via a flexible conduit that can be installed through a screwless frame for suspended ceilings or via a universal mounting plate that attaches directly to mesh trays, cable trays, and cable ladders. This provides installation flexibility across different building types and ceiling structures. The aluminium surfaces may be anodized or painted to protect the material from corrosion and enhance long-term durability. The product is intended for indoor use in office, educational, and commercial environments and is suitable for both new installations and refurbishment projects requiring reconfigurable and scalable service distribution.
Classification
Class name : Hierarchy level
  • One Click LCA: Material / Construction / All Constructions
General comment on data set An effective installation system in office environments is essential for ensuring reliable connectivity, flexibility, and long-term workspace efficiency. As modern interiors evolve toward modular layouts, adaptable cable distribution solutions are needed to support changing technology, varied workstyles, and sustainable building requirements. One of the key solutions within the Wibe Group installation systems portfolio is the free standing aluminium service pole, designed to route power and low voltage services from the ceiling to the workstation in a clean and space efficient manner. The pole is manufactured from 100% recycled aluminium, contributing to a reduced environmental footprint while maintaining structural strength and durability. The stabilizing foot is produced using scrap cast iron, further minimizing embodied carbon compared with components made from primary material. The system consists of a thin round visible pole above desk height, ensuring a discreet appearance suitable for modern office designs. At desk level, a slim service box provides space for power, data, and multimedia wiring devices, enabling efficient cable organization and ergonomic installation. The design accommodates both dedicated Wibe Group wiring devices and standard 80 mm wiring devices, ensuring compatibility with the wall installation trunking system. For ceiling integration, the pole connects via a flexible conduit that can be installed through a screwless frame for suspended ceilings or via a universal mounting plate that attaches directly to mesh trays, cable trays, and cable ladders. This provides installation flexibility across different building types and ceiling structures. The aluminium surfaces may be anodized or painted to protect the material from corrosion and enhance long-term durability. The product is intended for indoor use in office, educational, and commercial environments and is suitable for both new installations and refurbishment projects requiring reconfigurable and scalable service distribution.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Material properties of the reference flow
    • weight per piece: 16.174 kg
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 1.46E-5 kg
Time representativeness
Data set valid until 2027
Technological representativeness
Technology description including background system An effective installation system in office environments is essential for ensuring reliable connectivity, flexibility, and long-term workspace efficiency. As modern interiors evolve toward modular layouts, adaptable cable distribution solutions are needed to support changing technology, varied workstyles, and sustainable building requirements. One of the key solutions within the Wibe Group installation systems portfolio is the free standing aluminium service pole, designed to route power and low voltage services from the ceiling to the workstation in a clean and space efficient manner. The pole is manufactured from 100% recycled aluminium, contributing to a reduced environmental footprint while maintaining structural strength and durability. The stabilizing foot is produced using scrap cast iron, further minimizing embodied carbon compared with components made from primary material. The system consists of a thin round visible pole above desk height, ensuring a discreet appearance suitable for modern office designs. At desk level, a slim service box provides space for power, data, and multimedia wiring devices, enabling efficient cable organization and ergonomic installation. The design accommodates both dedicated Wibe Group wiring devices and standard 80 mm wiring devices, ensuring compatibility with the wall installation trunking system. For ceiling integration, the pole connects via a flexible conduit that can be installed through a screwless frame for suspended ceilings or via a universal mounting plate that attaches directly to mesh trays, cable trays, and cable ladders. This provides installation flexibility across different building types and ceiling structures. The aluminium surfaces may be anodized or painted to protect the material from corrosion and enhance long-term durability. The product is intended for indoor use in office, educational, and commercial environments and is suitable for both new installations and refurbishment projects requiring reconfigurable and scalable service distribution.

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Production
A1-A3
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 60.14
  • 60.03
  • 0.09668
  • -0.209
  • 0.1963
  • 0.003912
  • ND
  • 0.0002048
  • 0.143
  • 0.6879
  • 0.02156
  • -75.18
Input
  • 2.962
  • 2.965
  • 0
  • 0.002446
  • 0
  • -0.002446
  • ND
  • 0
  • 0
  • -1.777
  • -1.185
  • 0.000163
Input
  • 63.1
  • 62.99
  • 0.09668
  • -0.2065
  • 0.1963
  • 0.001467
  • ND
  • 0.0002048
  • 0.143
  • -1.089
  • -1.163
  • -75.18
Input
  • 576.5
  • 583.5
  • 7.055
  • -0.08328
  • 14.33
  • 0.005969
  • ND
  • 0.0007586
  • 10.43
  • 4.426
  • -65.11
  • -332
Input
  • 75.22
  • 74.13
  • 0
  • -1.093
  • 0
  • -0.0004998
  • ND
  • 0
  • 0
  • -11.67
  • -62.45
  • 0.000156
Input
  • 651.7
  • 657.6
  • 7.055
  • -1.176
  • 14.33
  • 0.00547
  • ND
  • 0.0007586
  • 10.43
  • -7.245
  • -127.6
  • -332
Input
  • 14.34
  • 14.34
  • 0.003003
  • 0.0003621
  • 0.006098
  • 0.000001241
  • ND
  • 1.22E-7
  • 0.004686
  • 0.005125
  • 0.0004367
  • 9.339
Input
  • 0.02862
  • 0.02873
  • 0.00003814
  • 0.00007531
  • 0.00007745
  • 5.754E-9
  • ND
  • 1.051E-9
  • 0.00005965
  • 0.000233
  • 0.000008112
  • -0.01053
Input
  • 2.18E-23
  • 2.18E-23
  • 0
  • 0
  • 0
  • 0
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.4843
  • 0.4855
  • 0.001043
  • 0.000173
  • 0.002118
  • 0.000007992
  • ND
  • 4.942E-7
  • 0.001382
  • 0.001933
  • -0.007951
  • -1.147
Output
  • 14.15
  • 14.16
  • 0.01195
  • 0.0048
  • 0.02427
  • 0.000006602
  • ND
  • 0.000001839
  • 0.01818
  • 0.03455
  • 0.003289
  • -16.14
Output
  • 210.2
  • 210.9
  • 0.2212
  • 0.5383
  • 0.4491
  • 0.0002391
  • ND
  • 0.0001549
  • 0.3409
  • 0.9716
  • 11.9
  • -907.8
Output
  • 0.001903
  • 0.001905
  • 0.000001504
  • 6.638E-7
  • 0.000003054
  • 9.356E-8
  • ND
  • 5.447E-9
  • 0.000002068
  • 0.000003912
  • 3.488E-7
  • -0.000425
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 1.728
  • 2.443
  • 0
  • 0.7148
  • 0
  • 0.0001786
  • ND
  • 0
  • 0
  • 13.8
  • 0
  • 0
Output
  • 0.00003733
  • 0.03594
  • 0
  • 0.0359
  • 0
  • 0
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
Output
No records found.
  • ND
No records found.
No records found.
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
Output
No records found.
  • ND
No records found.
No records found.
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND

IndicatorUnit Raw material supply
A1
Production
A1-A3
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
  • 5.4E+2
  • 547.4
  • 7.055
  • 0.3243
  • 14.32
  • 0.006156
  • ND
  • 0.0007586
  • 10.43
  • 4.426
  • 1.411
  • -332
  • 136.5
  • 136.5
  • 0.000001356
  • 0.000001163
  • 0.000002754
  • 5.494E-9
  • ND
  • 4.467E-10
  • 0.000002441
  • 0.00002211
  • 1.289E-7
  • -0.04414
  • 0.4509
  • 0.4528
  • 0.001658
  • 0.0002396
  • 0.003366
  • 5.781E-7
  • ND
  • 1.894E-7
  • 0.002478
  • 0.004013
  • 0.0004414
  • -8.047
  • 0.00000148
  • 0.000001488
  • 7.177E-9
  • 3.845E-10
  • 1.457E-8
  • 1.4E-12
  • ND
  • 6.113E-13
  • 1.039E-8
  • 4.033E-9
  • 1.634E-9
  • -2.086E-7
  • 0.01092
  • 0.01097
  • 0.00003785
  • 0.00001377
  • 0.00007685
  • 4.19E-8
  • ND
  • 3.158E-8
  • 0.00005781
  • 0.000203
  • 0.000006767
  • -0.1509
  • 0.04074
  • 0.04136
  • 0.0005446
  • 0.00007416
  • 0.001106
  • 9.192E-8
  • ND
  • 3.02E-8
  • 0.0008029
  • 0.0008914
  • 0.003961
  • -0.1069
  • 0.484
  • 0.4906
  • 0.005927
  • 0.0006479
  • 0.01203
  • 8.914E-7
  • ND
  • 2.674E-7
  • 0.008736
  • 0.01005
  • 0.001784
  • -1.553
  • -0.3726
  • -0.3501
  • 0.0001101
  • 0.02242
  • 0.0002236
  • 0.0002756
  • ND
  • 0
  • 0.0001623
  • -0.00112
  • -0.0001626
  • -0.05844
  • 36.87
  • 37.39
  • 0.4861
  • 0.03755
  • 0.987
  • 0.00004977
  • ND
  • 0.0000329
  • 0.7434
  • 0.375
  • 0.2134
  • -31.09
  • 0.05916
  • 0.05943
  • 0.0002175
  • 0.00004929
  • 0.0004416
  • 0.000005133
  • ND
  • 9.712E-8
  • 0.0003291
  • 0.000441
  • 0.00004919
  • -0.0415
  • 36.55
  • 37.1
  • 0.4864
  • 0.06001
  • 0.9877
  • 0.0003305
  • ND
  • 0.00003299
  • 0.7439
  • 0.3743
  • 0.2133
  • -31.19
  • 0.1667
  • 0.1694
  • 0.002443
  • 0.0001916
  • 0.004961
  • 2.412E-7
  • ND
  • 8.552E-8
  • 0.00345
  • 0.002961
  • 0.0006517
  • -0.7933
  • 17.66
  • 17.7
  • 0.03485
  • 0.008016
  • 0.07076
  • 0.0003377
  • ND
  • 0.00002122
  • 0.04837
  • 0.07005
  • 0.009778
  • -17.32

IndicatorUnit Raw material supply
A1
Production
A1-A3
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Incidence of disease due to PM emissions (PM) 2
  • 0.000003061
  • 0.000003113
  • 4.867E-8
  • 3.407E-9
  • 9.883E-8
  • 5.19E-12
  • ND
  • 6.741E-13
  • 5.899E-8
  • 5.6E-8
  • 9.532E-9
  • -0.000009719
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 3286
  • 3287
  • 0.998
  • 0.2568
  • 2.026
  • 0.001391
  • ND
  • 0.00105
  • 1.649
  • 2.569
  • 96.25
  • -2423
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 9.531E-8
  • 9.541E-8
  • 8.024E-11
  • 2.198E-11
  • 1.629E-10
  • 9.311E-14
  • ND
  • 9.818E-15
  • 1.264E-10
  • 3.004E-10
  • 3.548E-11
  • -3.751E-7
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 0.000003691
  • 0.000003697
  • 4.568E-9
  • 1.237E-9
  • 9.275E-9
  • 4.764E-12
  • ND
  • 5.346E-13
  • 6.527E-9
  • 1.918E-8
  • 6.295E-9
  • -0.00003902
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 3.066
  • 3.075
  • 0.006144
  • 0.002959
  • 0.01248
  • 0.0004382
  • ND
  • 0.00002125
  • 0.008439
  • 0.0159
  • 0.001427
  • -1.606
Soil quality index (SQP) 2
  • 126.5
  • 134.1
  • 7.105
  • 0.5189
  • 14.43
  • 0.001471
  • ND
  • 0.0001484
  • 6.228
  • 8.383
  • 2.841
  • -1005